IFB  CI1931G223G2

IFB CI1931G223G2

Air Conditioner 1.6 Ton 3 Star

Troubleshooting Guide

SYMPTOMPROBLEM CAUSESOLUTION
Less Cooling1. Short of gas 
2. Air Filter blocked
3. Fan Blower working slow
4. Indoor Motor working slow.
5. Condensor & Evaporator coil blocked
6. Room area bigger than AC capacity.
7. Outdoor Motor slow
8. Outdoor PCB faulty
9. Compresor pumping low
1. Explained to customer
2. AC Servicing done
3. Gas leakage repaired and gas refilled
4.Indoor PCB replaced
5.Indoor Motor replaced
6.Outdoor Motor replaced.
7.Outdoor PCB replaced.
8. Compressor replaced.
No Cooling1. System leakage
2. Outdoor Unit Not working
3. Machine working on Fan Mode
4. Wrong Temperature Selection 
1. Explained to customer
2. AC Servicing done
3. Gas leakage repaired and gas refilled
4. Correction done as per error code
Water Leakage1. Breakage of Drain hose Pipe
2. Blockage of Drain Pipe
3. Blockage of Drain Tray Water Outlet
4. Crack to Drain Tray Water Out Lug 
1 Check the orientation of installation
2.Service to be done
3 Replace of Part
Noise from Indoor1. Gas flow noise 
2. Air flow noise
3. Indoor Blower Fan noise
4. Outdoor noise tranfer to Indoor
5. Installation problem
6. Motor noise
7. Compressor faulty
1. Explained to customer
2. Installation corrected
3. Motor Assy checked and corrected
4. Indoor motor replaced
5. Fan blade replaced
6. Outdoor PCB replaced
7. Compressor replaced
8. Mufler added in the system.
Noise from Outdoor1. Outdoor Motor Noise
2. Compressor noise 
3. Part Touching noise
4. Installation problem
5. Outdoor PCB failure
1. Explained to customer
2. Installation corrected
3. Motor Assy checked and corrected
4. Outdoor motor replaced
5. Fan blade replaced
6. Outdoor PCB replaced.
7. Adjustment done
Foul smell from Indoor Unit1. Service Of Indoor Unit
2. Drainage location
3. Evaporator coil 
1. Explained to customer
2. Servicing done
3. Drain pipe location changed.
4. Evaporator coil replaced.
Swing not moving Left / Right 1. V-Vane Motor defective
2. Indoor PCB Defective
3. Vane Link damage
4. Vane Louvers damage
1. Adjustment done in assy
2. Vane Motor replaced
3. Vane Blade replaced
4. Indoor PCB replaced
Up/Down Swing not moving
Vane Not closing Complete
1.Vane blade defective
2. Vane Motor defective
3. Indoor PCB Defective
1. Adjustment done in assy
2. Vane Motor replaced
3. Vane Blade replaced
4. Indoor PCB replaced
Remote not sensing With Indoor Unit /
Remote Hang
1. Remote Battery drained
2. Remote button need to be press twice
3. Display pcb failure
1. Batteries replaced
2. Remote replaced
3. Display pcb replaced.

Display and Error Codes

DISPLAY MESSAGEPROBLEM CAUSESOLUTION
E0/E0-C0/E0-CIIDU and ODU communication failure IDU & ODU Wire checked and corrected
 Connecting wire replaced
 Indoor PCB replaced 
 Outdoor PCB replaced  
E1/E2/E3IDU coil temperature sensor failureSensor Wire connections checked and corrected
Sensor replaced
Outdoor PCB replaced 
E4AC cooling system abnormal (Gas leakage detection)
Indoor Coil Sensor defective
Indoor PCB failure.
SVC Valve closed.
All sensor locations checked and corrected
Sensor replaced.
Indoor PCB replaced.
Service valves checked and opened
Gas refilled
Gas leakage repaired and gas refilled
E6IDU PG fan motor
DC fan motor works abnormal
failure
Motor Wire connections checked and corrected
Motor/Blower assy checked and corrected
Motor replaced
Indoor PCB replaced 
E7/E8ODU ambient temperature sensor failure
ODU discharge temperature sensor failure
Sensor Wire connections checked and corrected
Sensor replaced
Outdoor PCB replaced 
EFODU DC fan motor failureMotor Wire connections checked and corrected
Motor/Blower assy checked and corrected
Outdoor PCB replaced
Motor replaced 
EEIndoor machine EE faultIndoor PCB replaced
EUVoltage abnormalInput power supply/wiring checked and corrected
Outdoor PCB replaced
F0Outdoor PCB DefectiveOutdoor PCB replaced
Compressor replaced
FEOutdoor machine FE faultOutdoor PCB replaced
F1/F2Compressor Rotor block
Compressor out-of-step fault
Compressor wire connections (UVW) checked and corrected
Outdoor PCB replaced 
Compressor replaced
F3Indoor fan zero-crossing detection abnormalIndoor PCB replaced
F4/F5Vac abnormal(Vac > 325 for 2- 5 sec or Vac <125 for 5 min)
Outdoor PCB Defective
Input power supply/wiring checked and corrected
Stabilizer installed
Outdoor PCB replaced 
F6The Compressor lack of phaseCompressor wire connections (UVW) checked and corrected.
Stabilizer installed
Outdoor PCB replaced 
F7/P0IPM Module temperature protection
IPM module protection -- IPM Overcurrent (Idc)
ODU coil cleaned
ODU PCB assy checked and corrected
ODU PCB replaced 
F84-Way Valve reversing abnormalConnection checked amd corrected
4-Way Valve replaced
Outdoor PCB replaced 
P1/P2Over and under voltage protection
Over current protection (Iac)
Input power supply/wiring checked and corrected
 Stabilizer installed
Outdoor PCB replaced 
P4/P6ODU discharge over temperature protection
ODU coil over temperature protection in cool mode
Sensor Wire checcked and corrected
ODU coil cleaned
ODU fan motor and fan assy checked and corrected
System leaked repaired and gas refilled
Sensor replaced
Outdoor PCB replaced
ODU motor replaced
P5IDU coil low temperature protectionSensor Wire checcked and corrected
IDU coil cleaned
System leaked repaired and gas refilled
Sensor replaced
Outdoor PCB replaced 
P8ODU ambient over & under temperature protectionODU instalaltion checked and corrected
Sensor location checked and corrected
Sensor value/wiring checked and corrected
Sensor replaced
ODU PCB replaced
P9Compressor driving protection (Load abnormal)Compressor wire connections (UVW) checked and corrected.
ODU location changed to well ventilated area
ODU coil cleaned
Outdoor PCB replaced 
Compressor replaced

Warranty Information

Your IFB Washing Machine is covered under a 4 Machine Warranty, 10 Year Motor Warranty with assured 10 Year Spares Support.

No Product Found

Service Ticket Status

Track service request.

Let Us Know Your Concern – We're Ready to Help!

Make a service or repair request

back-arrowBack to Service Ticket Status

Ticket Number: 9000139416

Under Review

Product

IFBDC-2324IKSU Direct | Cool Refrigerator Advance

Reported / Issue / Concern / Issue Description / Details

Red light blinking

Current/ Status / Progress / Service Action

Pending field visit