| DISPLAY MESSAGE | SYMPTOM | SOLUTION |
| tAP | No water/low water pressure. If water supply is not finished within 10 mins, the ‘tAP’ message will light up | Did you connect the inlet hose and open the water tap? |
| Is the inlet hose or water tap frozen? |
| Is the water supply shut OFF? |
| Does foreign matter block the inlet hose filter? |
| Is the hot inlet hose connected to the cold valve? |
| Is the cold inlet hose connected to the hot valve? |
| Is the water pressure low? |
| tAP | Continuous water supply | The inlet valve is defective. |
| The pressure sensor is defective. |
| he PCB is defective. |
| The pressure tube is loose or leaky? Please contact your nearest IFB Care for help. |
| Unb dor | The washer will not spin | If the clothes are collected on one side during spin and the drum becomes unbalanced, the spin operation will be interrupted and this unbalanced condition will be automatically corrected by the program. However, if the unbalanced condition is unchanged despite the automatic program, the ‘UnbL’ message will be displayed. |
| Make sure the laundry is spread out evenly in the tub/redistribute the load by hand. |
| Make sure the washing machine is levelled on a flat surface/level the appliance. |
| Is the lid (door) open? The ‘dor’ message will be displayed in this case. |
| drE | The washer will not drain If the drain is not finished within ~20 mins, the ‘drEr’ message will be displayed | Is the drain hose frozen? |
| Is the drain hose blocked by dirt? |
| Is the drain hose kinked or deformed? |
| Is the end of the drain hose immersed in water? |
| ACH | Input voltage is too high | Machine will start automatically after the voltage decreases to safe operating level. If this error display persists or occurs frequently, contact your electrician to locatethe fault in the electrical system |
| ACL | Input voltage is too low | Machine will start automatically after the voltage increases to the safe operating level. If this error display persists or occurs frequently, contact your electrician to locate the fault in the electrical system. |
| FRH/FRL | Input frequency is too high or low | Machine will start automatically after the frequency decreases (increases) to safe operating level. If this error display persists or occurs frequently, contact your electrician to locate the fault in the electrical system. |
| LSE | Load sensing error | The load sensing detects the weight of load is inferior. |
| Press the Power button to turn the power OFF |
| Press the Power button to turn the power ON. |
| Operate your washing machine again |
| Operate your washing machine again. This error will also be displayed in case of overloading of clothes/motor, overload/clutch malfunction or incorrect belt tension |
| If the error display persists or occurs frequently, contact your nearest IFB Care for help |
| Pr 5 | Water level sensing error | The water level sensing is inferior. Please contact your nearest IFB Care for help. |
| The motor is defective (open error). |
| Press the ‘Power’ button to turn the power OFF. |
| Press the ‘Power’ button to turn the power ON. |
| Operate your washing machine again. |
| If the error display persists or occurs frequently, contact IFB Care. |
| CPE | Capacitor error | The running capacitor is defective (open error). This error will also be displayed in case of overloading of clothes (above max capacity)/ motor overload. Contact IFB Care |
| Het | Overheating error | Error will be displayed during overheat condition.Restrat the machine to check the consistency of the error display. If the error display persists or occurs frequently. Contact IFB Care |
| | The washer will not operate at all | Is there a power failure? |
| Is the power supply cable correctly connected to an electrical outlet? |
| Is the electric fuse broken? |
| Did you turn ON the power? |
| Did you press the Start/Pause button? |